Material Insights · Understanding the Material World

Transformer and power converter: Footprint

Raw materials in one unit

Every commodity and chemical inside one unit, traced through its components by the site, with its emission factor and emissions

VariantMaterialAmount (kg)Emission factor (kg CO2e per kg)Emissions (kg CO2e)
DistributionSteel1102.51.922116.8
DistributionAluminium40514.85994
PowerSteel41,972.041.9280,586.3
PowerCopper8280.153.96532,830.8
InverterAluminium52.314.8774
InverterSteel21.41.9241.1
InverterCopper19.83.96578.5

Worked out from data

The site's estimate

Emissions of one unit worked out by the site from its materials and energy, for the world and India, with the share of mass covered by emission factors

VariantStagePlaceEmissions (kg CO2e)Mass covered by factors
DistributionMakingWorld8111100%
DistributionUseWorld277,960100%
DistributionMakingIndia8111100%
DistributionUseIndia406,623100%
PowerMakingWorld1.4 million100%
PowerUseWorld13.3 million100%
PowerMakingIndia1.99 million100%
PowerUseIndia19.5 million100%
InverterMakingWorld894100%
InverterUseWorld97,194100%
InverterMakingIndia894100%
InverterUseIndia142,184100%

Worked out from data

Energy to make it

Energy used to make one unit, by carrier and stage

Energy to make
  • El Electricity 10 million MJ · Manufacturing Power transformer (40 MVA, oil-immersed) 2,790,000 kWh of electricity to make an ABB 40 MVA unit, converted at 3.6 MJ per kWh (calculated); an old 2003 declaration for a different unit from the Matelec reference [4].
  • Ht Heat 170,640 MJ · Manufacturing Power transformer (40 MVA, oil-immersed) 47,400 kWh of heat, converted at 3.6 MJ per kWh (calculated) [4].

as of 2026-11-13

Energy in use

Energy one unit uses per year of use, by carrier

Energy in use
  • El Electricity 17,340 kWh per year · lifetime 35 years Distribution transformer (400 kVA, oil-immersed) Electricity lost as heat. Calculated from the declared losses at 70% load: (3.25 kW x 0.7 squared + 0.387 kW) x 8,760 hours [2].
  • El Electricity 832,286 kWh per year · lifetime 35 years Power transformer (40 MVA, oil-immersed) Electricity lost as heat: 29,129,995 kWh over 35 years divided by 35 (calculated); load loss 158.473 kW, no-load loss 17.358 kW, load factor 0.7 [3].
  • El Electricity 8488.6 kWh per year · lifetime 25 years Inverter (352 kW solar string) Electricity lost as heat and in standby: E_use 211,200 kWh plus E_standby 1,014 kWh over the 25-year service life, divided by 25 (calculated); E_use is 352 kW x 2,000 sunshine hours x 25 years x 1.2% loss [5].

as of 2026-11-13. Each row is the electricity lost by one unit, from its declaration's own loss model.

Emissions by stage

Published life-cycle emissions of one unit in four stages (making, logistics, use, end of life), with their split, place and variant

StageValueUnitShareVariantPlaceYearSource
Making5060kg CO2e per transformer2Distribution transformer (400 kVA, oil-immersed)India (made)2026Vijai declaration [2]: manufacturing 5.06E+03
Logistics457kg CO2e per transformer0.2Distribution transformer (400 kVA, oil-immersed)India (made)2026Calculated from [2]: distribution 57.4 plus installation 400
Use243,000kg CO2e per transformer97.4Distribution transformer (400 kVA, oil-immersed)India (made)2026Vijai declaration [2]: use and maintenance 2.43E+05, 35 years
End of life1010kg CO2e per transformer0.4Distribution transformer (400 kVA, oil-immersed)India (made)2026Vijai declaration [2]: end of life 1.01E+03
Making6469kg CO2e per transformer2.2Distribution transformer (400 kVA, oil-immersed)Hungary (made); grid mix not named2025Calculated from [1]: upstream 6.34E+03 plus core 1.29E+02 (unit 9141275628, 1,672 kg)
Logistics153kg CO2e per transformer0.1Distribution transformer (400 kVA, oil-immersed)Hungary (made); grid mix not named2025Calculated from [1]: distribution 1.53E+02 plus installation 1.90E-01
Use282,000kg CO2e per transformer97.6Distribution transformer (400 kVA, oil-immersed)Hungary (made); grid mix not named2025[1]: use 2.82E+05 over 35 years
End of life198kg CO2e per transformer0.1Distribution transformer (400 kVA, oil-immersed)Hungary (made); grid mix not named2025[1]: end of life 1.98E+02
Making258,000kg CO2e per transformer2.3Power transformer (40 MVA, oil-immersed)Lebanon (made); Italian grid mix in use2025Matelec declaration [3]: manufacturing stage 2.58E+05
Logistics14,460kg CO2e per transformer0.1Power transformer (40 MVA, oil-immersed)Lebanon (made); Italian grid mix in use2025Calculated from [3]: distribution 3.96E+03 plus installation 1.05E+04
Use11.1 millionkg CO2e per transformer96.8Power transformer (40 MVA, oil-immersed)Lebanon (made); Italian grid mix in use2025Matelec declaration [3]: use stage 1.11E+07, 35 years
End of life92,500kg CO2e per transformer0.8Power transformer (40 MVA, oil-immersed)Lebanon (made); Italian grid mix in use2025Matelec declaration [3]: end of life including deinstallation 9.25E+04
Making4260kg CO2e per inverter21.5Inverter (352 kW solar string)China (made); use modelled with PV and Italian grid electricity2023Sungrow declaration [5]: SG350HX manufacturing 4.26E+03
Logistics58kg CO2e per inverter0.3Inverter (352 kW solar string)China (made); use modelled with PV and Italian grid electricity2023Calculated from [5]: distribution 28.5 plus installation 29.5
Use15,500kg CO2e per inverter78.1Inverter (352 kW solar string)China (made); use modelled with PV and Italian grid electricity2023Sungrow declaration [5]: use and maintenance 1.55E+04, 25 years
End of life33.3kg CO2e per inverter0.2Inverter (352 kW solar string)China (made); use modelled with PV and Italian grid electricity2023Sungrow declaration [5]: end of life 3.33E+01

as of 2026-11-13. Shares are of the sum of the four stages (calculated). The declarations name their columns upstream, core or manufacturing, distribution, installation, use and maintenance, and end of life; making is upstream plus core (or manufacturing) and logistics is distribution plus installation, a mapping made by the site. Each use stage is the emissions of the electricity lost over the service life, with the declaration's own electricity: Italian grid for the Matelec unit [3], photovoltaic power for the inverter's load losses and Italian grid for its standby [5].

End of life

What happens to a unit when it is thrown away: collection, reuse, recycling and disposal shares, by place

RouteSharePlaceYearSource
Recycling of steel and copper (EPD scenario for the 40 MVA transformer; share of mass, calculated)70.2Lebanon (maker)2025[3]
Incineration of oil, wood and insulation, and paint (EPD scenario for the 40 MVA transformer; share of mass, calculated; 'other' materials, 0.7%, have no treatment listed)29.1Lebanon (maker)2025[3]
Recycling of metals in the inverter (EPD scenario)90China (maker)2023[5]
Landfill of metals in the inverter (EPD scenario)10China (maker)2023[5]
Recycling of plastics in the inverter (EPD scenario)60China (maker)2023[5]
Incineration of plastics in the inverter (EPD scenario)40China (maker)2023[5]

as of 2026-11-13

Recovered as

The commodities and chemicals recovered at end of life, with recovery rates

Recovered as
  • St Steel 100% recovered · Recycling Assumed in the 40 MVA declaration (42,979 kg of steel recycled) [3]; the inverter declaration assumes 90% for its metals [5].
  • Cu Copper 100% recovered · Recycling Assumed in the 40 MVA declaration [3]; these are scenario assumptions, not measured recovery.
  • Al Aluminium 90% recovered · Recycling Metals of the inverter are assumed 90% recycled and 10% landfilled [5].

as of 2026-11-13

End of life in India

Collection and recycling in India, including the informal sector

No source gives end-of-life data for India. The declarations assume that steel and copper are recycled and oil, paper and wood are burnt [3], and that 90% of an inverter's metals are recycled [5]. The US review contacted two transformer recyclers but reports no recovery rates [7]. These are declared scenarios, not measured rates.

as of 2026-11-13

Sources

  1. Liquid immersed distribution transformers with 400 kVA operating power (EPD-SE_DB-003, EPDITALY0263, issued 31 March 2022, updated 9 October 2025) Siemens Energy Distribution Transformers Kft., registered with EPDItaly, 2025, GWP table, unit 9141275628
  2. Environmental Product Declaration: TR-400 kVA Transformer, models 110081 and 110169 (EPDITALY1233) Vijai Electricals Ltd (India), registered with EPDItaly, 2026, Tables 4, 7 and 10
  3. Power Transformer 40 MVA, FPT1847100 (EPDITALY0935) Matelec SAL, registered with EPDItaly, 2025, Tables 3, 4, 5 and 23
  4. Environmental Product Declaration Power Transformers 40/50 MVA (ONAN/ONAF), registration S-P-00053 ABB T&D S.p.A., 2003
  5. Environmental Product Declaration: String Power Inverters SG350HX, SG285HX, SG320HX, SG333HX (EPDITALY0458) Sungrow Power Supply Co., Ltd., registered with EPDItaly, 2023, Tables 4-1, 4-2, 5-1 and 7-1
  6. Electric Grid Supply Chain Review: Large Power Transformers and High Voltage Direct Current Systems US Department of Energy, 2022, Executive summary and sections 2.1.4 and 2.1.6