Held back most by
Engineering
The ceiling is far away: with perfect machines a heat pump and heat engine would return all the electricity [11], and a modelled design reaches 64.9% [11]. Real plants fall well short, about 25% for a heater-and-steam rock store [1], so better compressors, turbines and heat exchangers would change the technology most. In India a 2022 study for the Ministry of Power finds about 67 GW of coal plant that could be converted [12].
The six layers
Mathematics, science, engineering, production, economics, and resources and rules: what each gives, the idea in plain words, the limit (hard or soft) and how close today is, what could unlock it, and the maths behind it
Six layers make a technology possible, from the mathematics underneath to the resources and rules it needs at world scale. A hard limit comes from mathematics or nature and can only be sidestepped; a soft limit moves with effort, scale, money or policy.
- 1 Mathematics Hard limit
Mathematics is the language of its physics
What it gives. The rule that ties a heat pump to a heat engine: one is the other run backwards.
The idea. A physical law makes the store work and mathematics writes it down, so the role is language. A heat pump's coefficient of performance is one over the efficiency of the engine [10], so a perfect heat pump and a perfect engine working between the same two temperatures cancel out and return all the work [11].
The limit. The product of the two can never exceed one, so no Carnot battery can return more than it took in [11].
What could unlock it. Nothing to unlock in the mathematics; the gap lies in real machines.
Show the maths
COPhp = 1 ÷ Eff- COPhp
- the heat pump's coefficient of performance: heat delivered for each unit of work
- Eff
- the efficiency of a heat engine working between the same temperatures
In plain words. A heat pump uses a little work to move a lot of heat uphill. An engine lets that heat fall back and gets work out. If both are perfect, the heat pump's gain exactly makes up for the engine's loss.
Worked example. Take 565°C (838.15 K) and 278°C (551.15 K), the top and bottom of the compression in NREL's charge cycle [11], as the two temperatures (assumed, for illustration), using TK = T°C + 273.15 [14]: EffC = 1 − 551.15 ÷ 838.15 = 0.342, so COPhp = 1 ÷ 0.342 = 2.92, and 2.92 × 0.342 = 1.00 (calculated) [9][10].
- 2 Science Hard limit
What it gives. A way to store electricity as a temperature gap, using a heat pump to make it and a heat engine to spend it.
The idea. The best efficiency of any engine is set only by the absolute temperatures of its hot and cold sides [9]. If the heat pump is swapped for an electric heater, the round trip can be no better than the engine, around 40% for a conventional steam cycle [11]. A heat-pump design keeps that loss small, and NREL models one at 64.9% [11].
The limit. The second law: no real heat engine can do as well as the Carnot efficiency [9], and the heat pump faces the same limit in reverse.
Share of electricity returned by a pumped thermal store
Today (2022): 64.9% · Limit: 100% · 65% of the way to the limit
Today is a modelled design value, not a measured plant: NREL's recuperated air Joule-Brayton cycle charging from 278°C to 565°C (2022) [11]. The limit is the same report's statement that if both heat pump and engine obey the Carnot limits the round trip is 100% [11]; that holds whatever the two temperatures, so it applies to this cycle too.
What could unlock it. A heat pump in place of a heater lifts the ceiling from the engine's efficiency to 100% [11].
HP Heat pumps, air conditioning and refrigeration
Show the maths
EffC = 1 − Tc ÷ Th- EffC
- the Carnot efficiency, the largest share of heat any engine can turn into work
- Tc
- the temperature of the cold side, in kelvin
- Th
- the temperature of the hot side, in kelvin
In plain words. Heat only does work as it falls from hot to cold. The further it falls, the more work you can get. With a simple heater, this number is the most you can ever get back.
Worked example. Hot store 565°C = 838.15 K, cold side 25°C = 298.15 K (assumed) [14]: 1 − 298.15 ÷ 838.15 = 0.64 (calculated) [9]. A real steam cycle gets about 40% [11], roughly 0.62 of that limit (calculated).
- 3 Engineering Soft limit Binds most today
What it gives. Compressors, turbines, heat exchangers and insulated stores of salt, sand or rock.
The idea. A 2022 review says Carnot batteries typically return 30% to 70% [1]. Siemens Gamesa's heater-and-steam rock store returns around 25% because of its steam cycle, with over 42% expected at larger scale [1]. Isentropic's demonstrator reached around 77% thermodynamic efficiency, excluding mechanical and electrical losses, while run at reduced power [1].
The limit. Irreversibilities in every compressor, turbine and heat exchanger; NREL says these put real designs at 40% to 80% depending on conditions [11].
What could unlock it. Better turbomachinery and closer temperature matching in the heat exchangers; NREL says the field is still relatively new with considerable scope for improved designs [11].
- 4 Production Soft limit
What it gives. Plants built from power-station parts: turbines, compressors, tanks and heat exchangers.
The idea. Some designs are still concepts, while others are in experimental and pilot operation [1]. In India, a 2022 study finds a technical potential of about 67 GW of coal plant that could be converted, mainly subcritical units 8 to 15 years old with enough remaining life [12].
The limit. No fleet yet; each plant is a pilot, so costs have not fallen through repeat builds.
What could unlock it. Converting coal plants reuses their turbines, steam cycle and grid link, which the study estimates could give a round trip of almost 50% [12].
- 5 Economics Soft limit
What it gives. A cheap cost for each extra hour of storage, against a high cost for the machines.
The idea. For one scaled-up design the review gives 350 to 797 euros a kW for power and 13 to 21 euros a kWh for storage [1]. For coal plant conversions the 2022 study gives current costs of 100 to 150 euros a kWh and levelised costs of 65 to 105 euros a MWh, from Chilean and European work, and 55 to 85 euros a MWh for Indian conditions; it stresses that the price of purchased power is a large part of that [12]. NREL's modelled minimum is USD 0.126 a kWh, plus or minus 0.03 [11].
The limit. Low round-trip efficiency multiplies the cost of charging power, so the store pays only with long hours of very cheap electricity [12].
What could unlock it. Higher efficiency, and lower Indian costs: the study estimates capital costs up to 45% lower if local equipment and services cost a third of European levels [12].
Show the maths
Csys = cE × h + cP- Csys
- the total cost of the plant for each kilowatt of power, in euros a kW
- cE
- the cost of the store for each kilowatt-hour it holds, in euros a kWh
- h
- how many hours the plant can run at full power, in hours
- cP
- the cost of the machines for each kilowatt of power, in euros a kW
In plain words. A Carnot battery has two parts. The machines are dear and you pay for them once. The hot tank is cheap and you pay a little more for each extra hour. So the longer it runs, the cheaper each hour becomes.
Worked example. With the review's low-end figures, 350 euros a kW and 13 euros a kWh [1], an 8 hour plant (assumed) costs 13 × 8 + 350 = 454 euros a kW, or 56.8 euros a kWh; a 16 hour plant (assumed) costs 13 × 16 + 350 = 558 euros a kW, or 34.9 euros a kWh (calculated) [15].
- 6 Resources and rules Soft limit
What it gives. Sites, grid connections and a place in national storage plans.
The idea. India's plan needs 73.93 GW of storage by 2031-32, split between pumped hydro and batteries [13], with no line for thermal electricity storage. The materials are steel, salt, sand or rock, and existing coal sites already hold the grid connections [12].
The limit. No slot in India's storage plan and no rules yet for paying a converted coal plant as storage; in our judgement this, not land or minerals, would bind at scale.
What could unlock it. The 2022 study was commissioned for India's Ministry of Power [12], so a conversion pilot at a coal plant is the obvious next step; no such decision was found.
as of 2026-11-24
Sources
- Review of Carnot Battery Technology Commercial Development (Novotny et al., Energies 15(2), 647) MDPI, 2022
- Carnot's Perfect Heat Engine: The Second Law of Thermodynamics Restated (College Physics 2e, section 15.4) OpenStax, 2022
- Applications of Thermodynamics: Heat Pumps and Refrigerators (College Physics 2e, section 15.5) OpenStax, 2022
- Integrated Heat Pump Thermal Storage and Power Cycle for CSP: Final Technical Report (NREL/TP-5700-79806, McTigue et al.) National Renewable Energy Laboratory, 2022
- Thermal Electricity Storage in India: Retrofitting Potential for Coal-Fired Power Plants in India (Haider and Weise, vgbe, December 2022) Indo-German Energy Forum Support Office and GIZ, for India's Ministry of Power and Germany's BMWK, 2022
- Central Electricity Authority notifies the National Electricity Plan for the period of 2022-32 Press Information Bureau, Ministry of Power, 2023
- Chapter 11 Key Equations (Physics, undated) OpenStax, 2026
- Utility-Scale Battery Storage (Annual Technology Baseline 2024) National Renewable Energy Laboratory, 2024