Heat and thermodynamics: engines, heat pumps and their limits: Key terms, quiz and sources
All courses / Understanding Engineering / Module 6: Heat and thermodynamics: engines, heat pumps and their limits Wrap-upHeat and thermodynamics: engines, heat pumps and their limits: review
Key terms
- Temperature
- A measure of the average energy of molecular jiggling, which decides the direction heat flows.
- Heat
- Energy that moves from one body to another because their temperatures differ.
- Internal energy
- The total energy stored in the motion and bonds of a body's molecules.
- Kelvin
- The absolute temperature scale, equal to Celsius plus 273, used wherever temperature ratios matter.
- Conduction
- Heat passing through a still material from molecule to molecule.
- Convection
- Heat carried by a moving fluid.
- Radiation
- Heat carried by electromagnetic waves, needing no material.
- Specific heat
- The energy needed to warm one kilogram of a material by one kelvin.
- Latent heat
- The energy taken in or given out when a material changes phase at constant temperature.
- First law of thermodynamics
- Energy is conserved: the change in stored energy equals heat added minus work done.
- Second law of thermodynamics
- Heat does not flow by itself from cold to hot, and total entropy never decreases.
- Entropy
- A measure of how widely energy is spread among the possible molecular states; heat Q at temperature T carries Q/T.
- Carnot limit
- The highest efficiency any heat engine can have between two temperatures: one minus cold over hot, in kelvin.
- Rankine cycle
- The steam loop of pump, boiler, turbine and condenser used in thermal power plants.
- Compression ratio
- The cylinder volume before the squeeze divided by that after it, which sets an engine's ideal efficiency.
- Combined cycle
- A gas turbine whose hot exhaust raises steam to run a second, steam turbine.
- Coefficient of performance
- Heat moved divided by work put in for a refrigerator or heat pump, often 3 to 5.
- Cogeneration
- Making electricity and useful heat together from one fuel supply.
Try it in the table
- Open 'Steam turbine' and 'Gas turbine'. Find the inlet temperature of each, write both in kelvin, and compute the Carnot limit against 300 K as in estimate 4. Say which has the greater room to improve and what stops it.
- Under 'Internal combustion engine' and 'Heavy-duty diesel engine', find a compression ratio for a petrol and a diesel engine. Compute the ideal efficiency 1 - r^-0.4 for each, and compare it with the real values in estimate 7.
- Open 'Air conditioner' and 'Refrigerator'. Take a rated cooling capacity and a rated power input, compute the COP, and compare it with the ideal value for 35 °C outside and 24 °C inside from estimate 8.
- Look at 'Heat pump'. Redo estimate 9 for a 200 litre tank heated from 22 °C to 60 °C, and find the electricity a COP of 3 saves per day against a geyser.
- Open 'Mineral wool insulation' and 'Insulating glass unit'. Find a thermal conductivity for the wool and a U-value for the window, then repeat estimate 1 for a 10 m2 window against 10 m2 of insulated wall.
- Open 'Aircraft engine' and 'Steam turbine'. Say how each rejects heat, and estimate, from estimate 5, the cooling water a 660 MW unit needs at 3 m3/MWh and 85 per cent load.
Final quiz
Which statement about heat, temperature and internal energy is correct?
Heat flows because of a temperature difference. The size of the store (internal energy) depends on how much material there is, so a large bucket of warm water can hold more than a small hot object.A 100 litre solar heater tank is warmed from 25 °C to 55 °C. About how much heat is needed?
Heat = 100 kg x 4.19 kJ/kg K x 30 K = 12,570 kJ, which is 3.5 kWh because 1 kWh is 3,600 kJ.Why does a pressure cooker cook faster?
Higher pressure raises the boiling point. Cooking reactions go faster at higher temperature, roughly doubling for each 10 K, so 20 K hotter is about four times quicker.A heat engine works between 813 K and 313 K. Its Carnot limit is about
1 - 313/813 = 1 - 0.385 = 0.615. Real plants reach 35 to 40 per cent because of finite temperature gaps, friction and other losses.Why does a cooling-tower plant use so little water compared with once-through cooling, even though both remove the same heat?
Latent heat of evaporation is about 70 times the heat absorbed by warming water 8 K, so evaporative cooling needs around 2 m3 per MWh against 143 m3 for once-through. The price is that the evaporated water is consumed.Why does a diesel engine reach higher efficiency than a petrol engine?
A higher compression ratio raises the ideal efficiency, and a diesel can use 16 to 20 because only air is compressed. Petrol mixtures would ignite early at such ratios.An air conditioner with a COP of 4 removes 2.0 kW of heat from a room. How much electricity does it use and how much heat does it discharge outdoors?
Work = 2.0 / 4 = 0.5 kW. Heat out = heat in + work = 2.5 kW. The electricity is also converted to heat outdoors.Cogeneration saves fuel mainly because
By taking steam at a useful temperature instead of expanding it to a vacuum, the plant turns waste heat into a product. In the worked example 21 per cent less fuel is needed than for separate plants.Sources for this module
- Bloomfield, How Things Work (Wiley, 2015) · ch. 7, 'Heat and Phase Transitions', sections 7.1 'Woodstoves', 7.2 'Water, Steam, and Ice' and 7.3 'Clothing, Insulation, and Climate'; ch. 8, 'Thermodynamics', sections 8.1 'Air Conditioners' and 8.2 'Automobiles'
- Kosky et al., Exploring Engineering (Academic Press, 2013) · ch. 4, 'Energy Conversion', sections 4.3 to 4.5 (kinds of energy, energy conversion, conservation of energy and the control boundary)
- Feynman, Leighton and Sands, The Feynman Lectures on Physics, vol. I (Caltech online edition) · further reading: ch. 39, 'The Kinetic Theory of Gases', https://www.feynmanlectures.caltech.edu/I_39.html
- Feynman, Leighton and Sands, The Feynman Lectures on Physics, vol. I (Caltech online edition) · further reading: ch. 40, 'The Principles of Statistical Mechanics', https://www.feynmanlectures.caltech.edu/I_40.html
- Feynman, Leighton and Sands, The Feynman Lectures on Physics, vol. I (Caltech online edition) · further reading: ch. 44, 'The Laws of Thermodynamics', https://www.feynmanlectures.caltech.edu/I_44.html
- Feynman, Leighton and Sands, The Feynman Lectures on Physics, vol. I (Caltech online edition) · further reading: ch. 45, 'Illustrations of Thermodynamics', https://www.feynmanlectures.caltech.edu/I_45.html
- Feynman, Leighton and Sands, The Feynman Lectures on Physics, vol. I (Caltech online edition) · further reading: ch. 46, 'Ratchet and Pawl', https://www.feynmanlectures.caltech.edu/I_46.html
- Powerline, 'Water stress: thermal power plants take steps to optimise consumption' (4 September 2026) · 2015 norms (3.5 m3/MWh for existing and once-through plants; 2.5 for plants from 2017), raised to 3 for new plants in June 2018, sea-water plants exempt; once-through withdrawal 70 to 200 m3/MWh (Centre for Science and Environment); tower plants about 4 m3/MWh; https://powerline.net.in/2026/09/04/water-stress-thermal-power-plants-take-steps-to-optimise-consumption/
- A Dataset of the Operating Station Heat Rate for 806 Indian Coal Plant Units using Machine Learning (arXiv, 2024) · mean heat rates of 12.91 and 11.17 MMBtu/MWh (subcritical) and 10.72 and 8.56 (supercritical) by two methods; https://arxiv.org/html/2410.00016v1
- Beating the Heat: How Air Conditioner Efficiency Standards Help India Avert Power Shortages and Cut Consumer Bills (Abhyankar, Domínguez Bennett and Phadke, India Energy and Climate Center, University of California, Berkeley, May 2026) · ISEER 5.3 as the current 5-star level; BEE's planned 4.3 minimum for 2028 and proposed minimums of 5.3 in 2030 and 6.7 in 2033; air conditioners up to 60 to 70 GW, about 25 per cent of peak demand; https://live-iecc-gspp.pantheon.berkeley.edu/resources/reports/beating-the-heat-ac-efficiency-standards/
- Power Engineering, 'HA Technology Now Available at Industry-First 64 Percent Efficiency' (read November 2026) · maker's claim of 64 per cent combined cycle efficiency; https://www.power-eng.com/renewables/ha-technology-now-available-at-industry-first-64-percent-efficiency/
- Guinness World Records, 'Most efficient combined cycle power plant' (verified 21 May 2024; read November 2026) · 64.18 per cent corrected gross efficiency under ISO conditions, Keadby 2, Siemens Energy; https://www.guinnessworldrecords.com/world-records/431420-most-efficient-combined-cycle-power-plant
- Central Electricity Authority, 'Fly Ash Generation at Coal/Lignite Based Thermal Power Stations and its Utilization in the Country for the 1st Half of the Year 2022-23' (March 2023) · ash content of coal consumed; https://cea.nic.in/wp-content/uploads/tcd/2023/05/Half_Yearly_Ash_Report_2022_23.pdf
- Press Information Bureau, Ministry of Power, star labelling programme and split air conditioners (10 May 2023) · split AC ISEER thresholds: 1-star 3.3 and 5-star 5.0 for the table in force from July 2022; https://www.pib.gov.in/PressReleaseIframePage.aspx?PRID=1923031®=48&lang=2
- Directive 2012/27/EU of the European Parliament and of the Council on energy efficiency (Official Journal of the European Union, 2012) · Annex II: high-efficiency cogeneration must give primary energy savings of at least 10 per cent against separate production of heat and power