Material Insights · Understanding the Material World

Heat and thermodynamics: engines, heat pumps and their limits: Key terms, quiz and sources

All courses / Understanding Engineering / Module 6: Heat and thermodynamics: engines, heat pumps and their limits Wrap-up

Heat and thermodynamics: engines, heat pumps and their limits: review

Key terms

Temperature
A measure of the average energy of molecular jiggling, which decides the direction heat flows.
Heat
Energy that moves from one body to another because their temperatures differ.
Internal energy
The total energy stored in the motion and bonds of a body's molecules.
Kelvin
The absolute temperature scale, equal to Celsius plus 273, used wherever temperature ratios matter.
Conduction
Heat passing through a still material from molecule to molecule.
Convection
Heat carried by a moving fluid.
Radiation
Heat carried by electromagnetic waves, needing no material.
Specific heat
The energy needed to warm one kilogram of a material by one kelvin.
Latent heat
The energy taken in or given out when a material changes phase at constant temperature.
First law of thermodynamics
Energy is conserved: the change in stored energy equals heat added minus work done.
Second law of thermodynamics
Heat does not flow by itself from cold to hot, and total entropy never decreases.
Entropy
A measure of how widely energy is spread among the possible molecular states; heat Q at temperature T carries Q/T.
Carnot limit
The highest efficiency any heat engine can have between two temperatures: one minus cold over hot, in kelvin.
Rankine cycle
The steam loop of pump, boiler, turbine and condenser used in thermal power plants.
Compression ratio
The cylinder volume before the squeeze divided by that after it, which sets an engine's ideal efficiency.
Combined cycle
A gas turbine whose hot exhaust raises steam to run a second, steam turbine.
Coefficient of performance
Heat moved divided by work put in for a refrigerator or heat pump, often 3 to 5.
Cogeneration
Making electricity and useful heat together from one fuel supply.

Try it in the table

  • Open 'Steam turbine' and 'Gas turbine'. Find the inlet temperature of each, write both in kelvin, and compute the Carnot limit against 300 K as in estimate 4. Say which has the greater room to improve and what stops it.
  • Under 'Internal combustion engine' and 'Heavy-duty diesel engine', find a compression ratio for a petrol and a diesel engine. Compute the ideal efficiency 1 - r^-0.4 for each, and compare it with the real values in estimate 7.
  • Open 'Air conditioner' and 'Refrigerator'. Take a rated cooling capacity and a rated power input, compute the COP, and compare it with the ideal value for 35 °C outside and 24 °C inside from estimate 8.
  • Look at 'Heat pump'. Redo estimate 9 for a 200 litre tank heated from 22 °C to 60 °C, and find the electricity a COP of 3 saves per day against a geyser.
  • Open 'Mineral wool insulation' and 'Insulating glass unit'. Find a thermal conductivity for the wool and a U-value for the window, then repeat estimate 1 for a 10 m2 window against 10 m2 of insulated wall.
  • Open 'Aircraft engine' and 'Steam turbine'. Say how each rejects heat, and estimate, from estimate 5, the cooling water a 660 MW unit needs at 3 m3/MWh and 85 per cent load.

Final quiz

Which statement about heat, temperature and internal energy is correct?

Heat flows because of a temperature difference. The size of the store (internal energy) depends on how much material there is, so a large bucket of warm water can hold more than a small hot object.

A 100 litre solar heater tank is warmed from 25 °C to 55 °C. About how much heat is needed?

Heat = 100 kg x 4.19 kJ/kg K x 30 K = 12,570 kJ, which is 3.5 kWh because 1 kWh is 3,600 kJ.

Why does a pressure cooker cook faster?

Higher pressure raises the boiling point. Cooking reactions go faster at higher temperature, roughly doubling for each 10 K, so 20 K hotter is about four times quicker.

A heat engine works between 813 K and 313 K. Its Carnot limit is about

1 - 313/813 = 1 - 0.385 = 0.615. Real plants reach 35 to 40 per cent because of finite temperature gaps, friction and other losses.

Why does a cooling-tower plant use so little water compared with once-through cooling, even though both remove the same heat?

Latent heat of evaporation is about 70 times the heat absorbed by warming water 8 K, so evaporative cooling needs around 2 m3 per MWh against 143 m3 for once-through. The price is that the evaporated water is consumed.

Why does a diesel engine reach higher efficiency than a petrol engine?

A higher compression ratio raises the ideal efficiency, and a diesel can use 16 to 20 because only air is compressed. Petrol mixtures would ignite early at such ratios.

An air conditioner with a COP of 4 removes 2.0 kW of heat from a room. How much electricity does it use and how much heat does it discharge outdoors?

Work = 2.0 / 4 = 0.5 kW. Heat out = heat in + work = 2.5 kW. The electricity is also converted to heat outdoors.

Cogeneration saves fuel mainly because

By taking steam at a useful temperature instead of expanding it to a vacuum, the plant turns waste heat into a product. In the worked example 21 per cent less fuel is needed than for separate plants.
Next module: Vibration, waves and resonance in machines and structures →

Sources for this module

  • Bloomfield, How Things Work (Wiley, 2015) · ch. 7, 'Heat and Phase Transitions', sections 7.1 'Woodstoves', 7.2 'Water, Steam, and Ice' and 7.3 'Clothing, Insulation, and Climate'; ch. 8, 'Thermodynamics', sections 8.1 'Air Conditioners' and 8.2 'Automobiles'
  • Kosky et al., Exploring Engineering (Academic Press, 2013) · ch. 4, 'Energy Conversion', sections 4.3 to 4.5 (kinds of energy, energy conversion, conservation of energy and the control boundary)
  • Feynman, Leighton and Sands, The Feynman Lectures on Physics, vol. I (Caltech online edition) · further reading: ch. 39, 'The Kinetic Theory of Gases', https://www.feynmanlectures.caltech.edu/I_39.html
  • Feynman, Leighton and Sands, The Feynman Lectures on Physics, vol. I (Caltech online edition) · further reading: ch. 40, 'The Principles of Statistical Mechanics', https://www.feynmanlectures.caltech.edu/I_40.html
  • Feynman, Leighton and Sands, The Feynman Lectures on Physics, vol. I (Caltech online edition) · further reading: ch. 44, 'The Laws of Thermodynamics', https://www.feynmanlectures.caltech.edu/I_44.html
  • Feynman, Leighton and Sands, The Feynman Lectures on Physics, vol. I (Caltech online edition) · further reading: ch. 45, 'Illustrations of Thermodynamics', https://www.feynmanlectures.caltech.edu/I_45.html
  • Feynman, Leighton and Sands, The Feynman Lectures on Physics, vol. I (Caltech online edition) · further reading: ch. 46, 'Ratchet and Pawl', https://www.feynmanlectures.caltech.edu/I_46.html
  • Powerline, 'Water stress: thermal power plants take steps to optimise consumption' (4 September 2026) · 2015 norms (3.5 m3/MWh for existing and once-through plants; 2.5 for plants from 2017), raised to 3 for new plants in June 2018, sea-water plants exempt; once-through withdrawal 70 to 200 m3/MWh (Centre for Science and Environment); tower plants about 4 m3/MWh; https://powerline.net.in/2026/09/04/water-stress-thermal-power-plants-take-steps-to-optimise-consumption/
  • A Dataset of the Operating Station Heat Rate for 806 Indian Coal Plant Units using Machine Learning (arXiv, 2024) · mean heat rates of 12.91 and 11.17 MMBtu/MWh (subcritical) and 10.72 and 8.56 (supercritical) by two methods; https://arxiv.org/html/2410.00016v1
  • Beating the Heat: How Air Conditioner Efficiency Standards Help India Avert Power Shortages and Cut Consumer Bills (Abhyankar, Domínguez Bennett and Phadke, India Energy and Climate Center, University of California, Berkeley, May 2026) · ISEER 5.3 as the current 5-star level; BEE's planned 4.3 minimum for 2028 and proposed minimums of 5.3 in 2030 and 6.7 in 2033; air conditioners up to 60 to 70 GW, about 25 per cent of peak demand; https://live-iecc-gspp.pantheon.berkeley.edu/resources/reports/beating-the-heat-ac-efficiency-standards/
  • Power Engineering, 'HA Technology Now Available at Industry-First 64 Percent Efficiency' (read November 2026) · maker's claim of 64 per cent combined cycle efficiency; https://www.power-eng.com/renewables/ha-technology-now-available-at-industry-first-64-percent-efficiency/
  • Guinness World Records, 'Most efficient combined cycle power plant' (verified 21 May 2024; read November 2026) · 64.18 per cent corrected gross efficiency under ISO conditions, Keadby 2, Siemens Energy; https://www.guinnessworldrecords.com/world-records/431420-most-efficient-combined-cycle-power-plant
  • Central Electricity Authority, 'Fly Ash Generation at Coal/Lignite Based Thermal Power Stations and its Utilization in the Country for the 1st Half of the Year 2022-23' (March 2023) · ash content of coal consumed; https://cea.nic.in/wp-content/uploads/tcd/2023/05/Half_Yearly_Ash_Report_2022_23.pdf
  • Press Information Bureau, Ministry of Power, star labelling programme and split air conditioners (10 May 2023) · split AC ISEER thresholds: 1-star 3.3 and 5-star 5.0 for the table in force from July 2022; https://www.pib.gov.in/PressReleaseIframePage.aspx?PRID=1923031&reg=48&lang=2
  • Directive 2012/27/EU of the European Parliament and of the Council on energy efficiency (Official Journal of the European Union, 2012) · Annex II: high-efficiency cogeneration must give primary energy savings of at least 10 per cent against separate production of heat and power