Vibration, waves and resonance in machines and structures: Controlling vibration: isolation, tuned masses and noise
All courses / Understanding Engineering / Module 7: Vibration, waves and resonance in machines and structures Part 4 of 5Controlling vibration: isolation, tuned masses and noise
Once you know where a vibration comes from and where it resonates, there are four moves: cut the path, change the frequency, add damping, or add a second mass that fights the first. This part covers each, with a generator set on springs, a tall tower with a swinging ball, and the noise from the same generator set at a neighbour's window.
4.1 Vibration isolation works by mounting a machine on springs so soft that the shaking is well above their natural frequency
Recall the third regime from part 2: when the driving is much faster than the natural frequency, the supported mass barely moves, and very little force passes through the spring. Isolation uses that. Put the machine on soft mounts whose natural frequency is far below the machine's shaking frequency, and the floor feels only a small part of the force.
The fraction of force that gets through is called transmissibility. For a lightly damped mount it is about 1 / (r^2 - 1), where r is the ratio of shaking frequency to natural frequency. It is only below 1 when r exceeds 1.4. At r = 3 about 12% passes; at r = 5, about 4%; at r = 10, 1%. So the aim is a ratio of at least 3 and preferably more.
The sag shortcut from estimate 1 tells how soft: the natural frequency is 0.5 / square root of the static sag in metres. To get a natural frequency of 5 Hz, a mount must sag 10 mm under the machine's weight. To get 2.5 Hz it must sag 40 mm. Estimate 12 follows this for a diesel generator set. Softer mounts isolate better, but they sag more, let the machine rock under torque and make a pipe or cable connected to it a weak spot. A rigid pipe bolted to a spring-mounted engine bridges the isolation and sends the shake straight into the building, so pipes and cables on isolated machines use flexible connectors.
Damping is also a compromise. Some damping is needed to keep the resonance crossing at start-up and shutdown under control. Too much damping spoils the isolation at high frequency, since a damper is a rigid path for fast motion. The same idea appears in the secondary suspension of a 'Railway locomotive and coach', and in the floating slabs used under tracks in an 'Underground railway'.
| Mount sag under load | Natural frequency = 0.5 / square root of sag (Hz) | Ratio r = 25 / f | Force passing = 1 / (r^2 - 1) |
|---|---|---|---|
| 2 mm | 11.2 | 2.2 | 25% |
| 5 mm | 7.1 | 3.5 | 9% |
| 10 mm | 5.0 | 5.0 | 4% |
| 25 mm | 3.2 | 7.9 | 1.6% |
| 50 mm | 2.2 | 11.2 | 0.8% |
A 2,000 kg set pushing with, say, a 4 kN rotating force would send 160 N into the floor on 10 mm springs, against 4,000 N if bolted down. Start-up crosses the 5 Hz resonance (300 rpm) in a second or two, which springs with some damping allow. Check: about 96% isolation from 10 mm of sag is a good everyday result, and going softer buys little more.
Source: Bloomfield, How Things Work (Wiley, 2015), ch. 9, 'Resonance and Mechanical Waves'- Bloomfield, How Things Work (Wiley, 2015) · ch. 9, 'Resonance and Mechanical Waves'
4.2 Tuned mass dampers add a second, small mass that moves against a tall structure and soaks up its sway
There are three ways to stop a structure resonating. Move its natural frequency by changing stiffness or mass. Add damping, so that it cannot build up. Or add a tuned mass damper: a smaller mass on a spring, set to the same natural frequency as the structure. When the structure starts to sway, the damper mass swings too, but a quarter of a cycle behind. Its inertia then pushes against the structure's motion, and a damper element, such as oil dashpots or friction, turns the motion into heat.
Tuned mass dampers suit tall slender towers and long footbridges because those have little natural damping and are very sensitive to wind and crowds. The usual size is about 1% of the moving mass of the structure. For a pendulum-type damper hung from the ceiling, the tuning is simple: pendulum length = g / (4 x pi^2 x frequency^2). Estimate 13 puts numbers on a 200 m tower.
The best-known example is the 508 m Taipei 101 tower, completed in 2004, which carries a steel ball of 660 tonnes hung between the 87th and 92nd floors. In a typhoon in 2015 it swung about 1 m, against an allowed 1.5 m. On the Millennium Bridge, some 50 tuned mass dampers worked beside 37 viscous dampers to lift the damping to a safe level.
There are limits. A tuned damper only works well near its design frequency, so if the structure changes (by cracking, or by added cladding) it can drift out of tune. It also takes space that could have been rented, and a large mass at the top has to be carried by the structure. Designers weigh that cost against shaping the tower to shed wind forces, which takes no floor area.
| Step | Working | Result |
|---|---|---|
| Natural period of the tower | Taken as 5 s (see the building-period rule in part 5: 0.075 x 200^0.75 = 4.0 s, then softer from cladding and soil) | 5 s, so f = 0.2 Hz |
| Moving (modal) mass of the tower | Assume about 40,000 tonnes taking part in the first sway | 40,000 t |
| Damper mass at 1% of that | 0.01 x 40,000 | 400 t |
| If hung as a pendulum, length | 9.81 / (4 x 9.87 x 0.04) | 6.2 m, a few floors of height |
| Compare with Taipei 101 | 660 t, between the 87th and 92nd floors | similar order of size |
| Effect on resonant response | Tower alone: damping ratio 0.01 (assumed), so magnification 1 / 0.02 = 50. With the damper the effective ratio might reach about 0.04 (assumed): 1 / 0.08 | about 12, four times smaller |
The 1% mass ratio is a common design figure, not a rule. The modal mass is an assumption for illustration. Check: Taipei 101's ball hangs over five floors, so a long cable is normal, and a tower with a longer period needs a longer pendulum. See the Guinness World Records entry for the largest tuned mass damper and Britannica for the building.
Source: Guinness World Records, 'Largest tuned mass damper' (read November 2026), 660 tonnes; Taipei 101, 508 m; between the 87th and 92nd floors; maximum extension 1.5 m; largest recorded swing 1 m in Typhoon Soudelor, August 2015; https://www.guinnessworldrecords.com/world-records/774616-largest-tuned-mass-damper- Bloomfield, How Things Work (Wiley, 2015) · ch. 9, 'Resonance and Mechanical Waves'
- Guinness World Records, 'Largest tuned mass damper' (read November 2026) · web
- Encyclopaedia Britannica, 'Taipei 101' (read November 2026) · completed 2004; 508 m including the spire; https://www.britannica.com/place/Taipei-101
4.3 Noise is vibration that escapes into the air, and a generator set shows how each step in the path can be cut
Noise from a machine travels by two routes. Some leaves the casing and the exhaust directly through the air. Some goes through the mounts and floor into the building, where walls and ducts re-radiate it as a hum in distant rooms. A noise cure must block the path that carries the most energy. Springs and flexible joints cut the second route, as in estimate 12. Enclosures and mufflers cut the first.
On a diesel generator set, fuel burns in the cylinders in sharp pulses, which shake the block and alternator and make the casing ring. The exhaust blows out pulses of its own, and the cooling fan pushes a large flow of air through openings. A set must breathe, so an enclosure needs silenced openings for air in and out. A heavier wall blocks more, about 6 dB for each doubling of its mass per square metre, so thin sheet metal alone does little.
In India the rules set a ceiling of 75 dB(A) measured 1 m from the enclosure for new diesel sets up to 1,000 kVA, made on or after 1 January 2005 (Central Pollution Control Board). Estimate 14 shows why that figure does not settle the matter. In the open, the level falls by 6 dB for each doubling of distance, but a neighbour in a narrow lane may be only 10 m away, and the ambient standard for a residential area under the Noise Pollution (Regulation and Control) Rules, 2000, is 55 dB(A) by day and 45 dB(A) at night (10 pm to 6 am), far below the limit at the set.
The usual answers are a longer exhaust, a barrier wall, siting the set away from boundaries and limiting night running. The trade-off is that a better silencer adds back-pressure, which costs engine power, and a tighter enclosure traps heat that the cooling air must then carry out.
| Question | Working | Result |
|---|---|---|
| Level of a bare set at 1 m (assumed for illustration) | taken as a round figure | 98 dB(A) |
| Enclosure with 25 dB(A) insertion loss, at 1 m | 98 - 25 | 73 dB(A), under the 75 limit |
| At 5 m in the open | 73 - 20 x log10(5) = 73 - 14 | 59 dB(A) |
| At 10 m | 73 - 20 | 53 dB(A), above the 45 night standard |
| Distance at which 45 dB(A) is reached | drop needed 28 dB; 10^(28/20) = 25 | about 25 m |
| Two such sets running together | 73 + 3 = 76 at 1 m; drop needed 31 dB; 10^(31/20) = 36 | about 36 m |
Assumes a small source in open air. A wall beside the set reflects sound and adds up to 3 to 6 dB, so real distances are longer. The 75 dB(A) limit is from the CPCB standard; its 25 dB(A) figure is the minimum insertion loss it asks of enclosures and exhaust mufflers for sets outside that limit, used here as a round illustration. The 45 dB(A) night figure is the residential standard in the schedule of the Noise Pollution (Regulation and Control) Rules, 2000. Check: a result of about 25 m is why generator sets in dense housing blocks so often draw complaints at night.
Source: Central Pollution Control Board, India, standard for diesel generator sets up to 1,000 kVA (G.S.R. 371(E), 17 May 2002, as amended), 75 dB(A) at 1 m from the enclosure for sets made on or after 1 January 2005; insertion loss of at least 25 dB(A) for enclosure and for exhaust muffler; https://cpcb.nic.in/uploads/Standerds/Generator-Set/divisionsofheadoffice/generator1000diesel.pdf- Bloomfield, How Things Work (Wiley, 2015) · ch. 9, 'Resonance and Mechanical Waves'
- Central Pollution Control Board, India, standard for diesel generator sets up to 1,000 kVA (G.S.R. 371(E), 17 May 2002, as amended) · web
See it in the table
St SteelPls PulsesCheck your understanding
A machine shakes at 25 Hz. Which mount gives the best isolation?
Isolation needs the natural frequency far below the shaking frequency. A mount at 25 Hz would resonate, and a rigid base transmits everything.A tuned mass damper is designed for a tower's first sway frequency. After years the tower's frequency shifts a little. What is the likely result?
A tuned damper is effective near its design frequency. If the structure's frequency drifts, the damper's motion falls out of step and its absorption drops.A generator set gives 73 dB(A) at 1 m. Roughly what level would you expect 10 m away in the open?
Each factor of 10 in distance lowers the level by 20 dB, so 73 - 20 = 53 dB(A).