Heat exchanger: Use case
Use cases
Each use, its share of demand and volume, how critical the product is to it and why, and the price paid
| Use case | Share of demand | Criticality | Reason | Year | Source |
|---|---|---|---|---|---|
| Chemical industry | 27% | Important | Shell and tube units can do the job at lower upfront cost but are bulkier and heavier. | 2025 | [9][27] |
| Food and beverage (India gasketed units) | 49% | Important | Sanitary, easy-to-clean plate units suit dairy and food processing; shell and tube is the costlier fallback. | 2021 | [13][11] |
| HVAC, refrigeration and district heating and cooling | – | Important | Plate units give close temperature approaches in little floor space; shell and tube needs more room. | 2025 | [11][6][18] |
| Marine, sugar, pulp and paper, mining, biogas and other heavy industry | – | Important | Shell and tube can take over at a size and weight penalty, and is preferred at the highest pressures and temperatures. | – | [18][27] |
as of 2026-11-17
Industries that buy it
The industries and kinds of firm that buy it, for which use case, and how critical it is to them
Used by 5- Bulk inorganic chemical suppliers Chemical industry · criticality important · 27% share The chemical segment was about 27% of plate heat exchanger market value in 2025 [9]; the catalogue has no chemicals industry node, so bulk inorganic chemical makers stand for it.
- Flour mills, oilseed crushers, sugar mills and dairies Dairy, sugar and food processing · criticality important Dairy, food, beverage and sugar are named among the uses of plate units [18]; Seligman's design helped bring in modern milk pasteurisation [16].
- Integrated virgin-fibre paper and paperboard mills Pulp and paper · criticality important The pulp and paper industry is among the listed uses [18].
- Colocation and wholesale data-centre operators Data centre cooling · criticality important Alfa Laval names data centres and free-cooling systems among the applications for its certified gasketed units [25].
- Real estate Building HVAC and district heating substations · criticality important HVAC is the first industry named for Danfoss plate units, and EN 1148 sets test procedures for district heating exchangers [18][23].
as of 2026-11-17
How it is used
Lifetime, use per year and utilisation, by variant
| Measure | Value | Unit | Variant | Place | Year | Source |
|---|---|---|---|---|---|---|
| Lifetime assumed in a Swedish life cycle assessment of heat exchangers, including an Alfa Laval T35-PFM plate unit of 8,810 kg | 30 | years | Gasketed | Sweden | 2016 | [20] |
| Age of Alfa Laval gasketed units still working when audited in Saudi Arabia, with gaskets approaching the end of their life | 11 | years | Gasketed | Saudi Arabia | 2025 | [26] |
| Rule-of-thumb pressure drop for HVAC cooling pressure breakers | 50 to 70 | kPa | Gasketed | World | – | [8] |
| Rule-of-thumb pressure drop for geothermal heating | 80 to 160 | kPa | Gasketed | World | – | [8] |
as of 2026-11-17
Prices
Unit prices by market or use, with year and source
| Market | Value | Unit | Source |
|---|---|---|---|
| HVAC cooling, one gasketed unit of 2,000 kW, 287 m3/h, designed for 20 kPa pressure drop (Alfa Laval worked case, EUR) | 49,277 | EUR per unit of 2,000 kW | [8] |
| Same duty designed for 50 kPa pressure drop (EUR) | 38,556 | EUR per unit of 2,000 kW | [8] |
| Same duty designed for 70 kPa pressure drop (EUR) | 34,810 | EUR per unit of 2,000 kW | [8] |
| Same duty at 20 kPa, per kW (calculated: 49,277 divided by 2,000) | 24.6 | EUR per kW | [8] |
| Same duty at 70 kPa, per kW (calculated: 34,810 divided by 2,000) | 17.4 | EUR per kW | [8] |
as of 2026-11-17. The Alfa Laval document gives no year. These are one maker's example prices for a single duty, not market averages.
Sources
- Gasketed plate heat exchangers: GPHE vs shell-and-tube Alfa Laval
- Save now, save later: what is the ideal pressure drop to specify for gasketed plate heat exchangers in HVAC applications Alfa Laval
- Plate Heat Exchanger Market Size & Share 2026-2035 Global Market Insights, 2026
- Plate & Frame Heat Exchanger Market (press release) MarketsandMarkets, 2025
- India Gasketed Plate Heat Exchanger Market Expected to Reach $276.2 Million by 2031 (press release) Allied Market Research, 2022
- Richard Seligman Society of Chemical Industry
- Traditional plate heat exchangers Danfoss
- Life Cycle Assessment and Life Cycle Cost of Heat Exchangers (master's thesis by Marcus Adolfsson and Shivan Rashid) Chalmers University of Technology, 2016
- EN 1148: Heat exchangers, water to water exchangers for district heating, test procedures for establishing the performance data NSAI Standards (I.S. EN 1148:1999), 1999
- Gasketed plate heat exchangers (leaflet) Alfa Laval
- Predicting gasket lifetime with Alfa Laval Performance Audit (Jubail, Saudi Arabia) Alfa Laval, 2025
- Plate Heat Exchanger vs Shell & Tube Heat Exchanger: Key Differences Alfa Laval India, 2026